Building and Environment ; : 110022, 2023.
Article in English | ScienceDirect | ID: covidwho-2177027

ABSTRACT

In sparsely occupied large industrial and commercial buildings, large-diameter ceiling fans1 (LDCFs) are commonly utilized for comfort cooling and destratification;however, a limited number of studies were conducted to guide the operation of these devices during the COVID-19 pandemic. This study conducted 223 parametrical computational-fluid-dynamics (CFD) simulations of LDCFs in the U.S. Department of Energy warehouse reference building to compare the impacts of fan operations, index-person, and worker-packing-line locations on airborne exposures to infectious aerosols under both summer and winter conditions. The steady-state airflow fields were modeled while transient exposures to particles of varying sizes (0.5–10 μm) were evaluated over an eight-hour period. Both the airflow and aerosol models were validated by measurement data from the literature. It was found that it is preferable to create a breeze from LDCFs for increased airborne dilution into a sparsely occupied large warehouse, which is more similar to an outdoor scenario than a typical indoor scenario. Operation of fans at the highest feasible speed while maintaining thermal-comfort requirements consistently outperformed the other options in terms of airborne exposures. There is no substantial evidence that fan reversal is beneficial in the current large space of interest. Reversal flow direction to create upward flows at higher fan speeds generally reduced performance compared with downward flows, as there was less airflow through the fan blades at the same rotational speed. Reversing flow at lower fan speeds decreased airflow speeds and dilution in the space and, thus, increased whole-warehouse concentrations.

2.
Indoor Air ; 32(1): e12917, 2022 01.
Article in English | MEDLINE | ID: covidwho-1388295

ABSTRACT

Tracer gas experiments were conducted in a 158 m3 room with overhead supply diffusers to study dispersion of contaminants from simulated speaking in physically distanced meeting and classroom configurations. The room was contained within a 237 m3 cell with open plenum return to the HVAC system. Heated manikins at desks and a researcher operating the tracer release apparatus presented 8-9 thermal plumes. Experiments were conducted under conditions of no forced air and neutral, cooled, or heated air supplied at 980-1100 cmh, and with/out 20% outdoor air. CO2 was released at the head of one manikin in each experiment to simulate small (<5 µm diameter) respiratory aerosols. The metric of exposure relative to perfectly mixed (ERM) is introduced to quantify impacts, based on measurements at manikin heads and at three heights in the center and corners of the room. Chilled or neutral supply air provided good mixing with ERMs close to one. Thermal stratification during heating produced higher ERMs at most manikins: 25% were ≥2.5 and the highest were >5× perfectly mixed conditions. Operation of two within-zone air cleaners together moving ≥400 cmh vertically in the room provided enough mixing to mitigate elevated exposure variations.


Subject(s)
Air Pollution, Indoor , Ventilation , Air Conditioning , Air Movements , Heating
3.
Appl Energy ; 292: 116848, 2021 Jun 15.
Article in English | MEDLINE | ID: covidwho-1279532

ABSTRACT

Radiant cooling-assisted natural ventilation is an innovative technical approach that combines new radiant cooling technology with natural ventilation to increase fresh air delivery into buildings year-round with minimal energy cost and improvment of air quality. Currently, the standard paradigm for HVAC (heating, ventilation and air conditioning) is based on central air systems that tie the delivery of heating and cooling to the delivery of fresh air. To prevent heat loss, the delivery of fresh air must be tightly controlled and is often limited through recirculation of already heated or cooled air. Buildings are designed with airtight envelopes, which do not allow for natural ventilation, and depend on energy-intensive central-air systems. As closed environments, buildings have become sites of rapid COVID-19 transmission. In this research, we demonstrate the energy cost of increasing outdoor air supply with standard systems per COVID-19 recommendations and introduce an alternative HVAC paradigm that maximizes the decoupling of ventilation and thermal control. We first consider a novel analysis of the energy costs of increasing the amount of conditioned fresh air using standard HVAC systems to address COVID-19 concerns. We then present an alternative that includes a novel membrane-assisted radiant system we have studied for cooling in humid climates, in place of an air conditioning system. The proposed system can work in conjunction with natural ventilation and thus decreases the risk of indoor spread of infectious diseases and significantly lowers energy consumption in buildings. Our results for modeling HVAC energy in different climates show that increasing outdoor air in standard systems can double cooling costs, while increasing natural ventilation with radiant systems can halve costs. More specifically, it is possible to add up to 100 days' worth of natural ventilation while saving energy when coupling natural ventilation and radiant systems. This combination decreases energy costs by 10-45% in 60 major cities globally, while increasing fresh air intake.

4.
Indoor Air ; 31(5): 1625-1638, 2021 09.
Article in English | MEDLINE | ID: covidwho-1153511

ABSTRACT

The use of Ultraviolet Germicidal Irradiation (UVGI) devices in the upper zones of occupied buildings has gained increased attention as one of the most effective mitigation technologies for the transmission of COVID-19. To ensure safe and effective use of upper-room UVGI, it is necessary to devise a simulation technique that enables engineers, designers, and users to explore the impact of different design and operational parameters. We have developed a simulation technique for calculating UV-C fluence rate within the volume of the upper zone and planar irradiance in the lower occupied zone. Our method is based on established ray-tracing light simulation methods adapted to the UV-C wavelength range. We have included a case study of a typical hospital patient room. In it, we explored the impact of several design parameters: ceiling height, device location, room configuration, proportions, and surface materials. We present a spatially mapped parametric study of the UV-C irradiance distribution in three dimensions. We found that the ceiling height and mounting height of the UVGI fixtures combined can cause the largest variation (up to 22%) in upper zone fluence rate. One of the most important findings of this study is that it is crucial to consider interreflections in the room. This is because surface reflectance is the design parameter with the largest impact on the occupant exposure in the lower zone: Applying materials with high reflectance ratio in the upper portion of the room has the highest negative impact (over 700% variation) on increasing hot spots that may receive over 6 mJ/cm2 UV dose in the lower occupied zone.


Subject(s)
Air Pollution, Indoor/prevention & control , Disinfection/methods , Patients' Rooms , Spatial Analysis , Ultraviolet Rays , COVID-19/prevention & control , Facility Design and Construction , Humans , SARS-CoV-2